Commercial Ice Machines

Commercial Ice Machines - GT360

Ice Machine

Commercial Ice Machine GT-360
Commercial Ice Machine - GT360 - shown with B400 Bin
KOLD-DRAFT Commercial Ice machines Features
KOLD-DRAFT Commercial Ice Machines produce full and half ice cubes, come with a 3-year warranty, and meet new energy standards!

The Impact

Even if you don't need a ton of ice, you can still make a large impact with your customers. The KOLD-DRAFT GT360 Impact Series produces up to 321 lbs. of KOLD-DRAFT’s exclusive "square cube," known for its perfect shape, purity, hardness, and slower melt rate. That means it not only looks better, but also lasts longer in storage bins, cocktail sinks, drinks, salad bars, bags, and coolers. And KOLD-DRAFT equipment offers some of the best recovery rates in the industry. You get more ice, more often.

KOLD-DRAFT commercial ice machines feature a unique "upside-down" horizontal evaporator and water plate assembly. As water is sprayed upward into the evaporator cells, the pure water freezes first while particulates and air are forced out and dumped at the end of each cycle. This leaves only perfect crystal-clear cubes, nearly as pure as distilled water.

The GT360 Series' rugged unibody construction and time-proven design ensure reliable operation, greater water efficiency, and maximum ice-making capacity. Plus, they are energy efficient, using environmentally friendly R-404A refrigerant. To facilitate maintenance, the GT360 is serviceable from the front and is armed with our 3-year "bumper-to-bumper" warranty on all parts and labor.

 

 

 

 

 

 

General Specifications for GT360 Series

Plumbing: 3/8" FPT potable water inlet.
1" FPT bin drain.
3/4" I.D. flex tubing cuber drain.
3/8" FPT condenser (liquid-cooled) inlet.
1/2" FPT condenser (liquid-cooled) outlet.
Exterior Finish: 300 Series stainless steel.
Refrigeration System: Thermostatic expansion valve-controlled R-404A-HFC.
Clearance Requirements: Allow 4" left side, 4" right side and back, and 1" top for ventilation and utility connections.
Condenser Heat Rejection: BTUH/kW/Ton
4,700/1.38/0.39 avg.
5,850/1.71/0.49 peak

 

Recommended Operating Requirements:

  Min. Max.
Room Air Temp. 45ºF (7ºC) 110ºF (43ºC)
Water Temperatures 45ºF (7ºC) 90ºF (32ºC)
Voltage 208-230 198V 253V
Voltage 115 104V 126V
Potable Water Pressure 20 PSIG (137 kPa) 100 PSIG (689 kPa)
Liquid-Cooled Condenser
Pressure
20 PSIG (137 kPa) 100 PSIG (689 kPa)

 

GT360 Series Daily Capacities: Lbs. of ice per 24 hours per unit

Model
Number
Description Capacity and Energy Input Ratings1 Water Use1 gal/100# (l/kg) Min. Circuit Amp2 Max.
Fuse Amps
Volt/
Hz/Ph
Cond-enser Cube
Size
90/70
Ambient/ Water
kWh/ 100#
(kJ/kg)
Tier 70/50
Ambient/ Water
kWh/ 100#
(kJ/kg)
Pot-able Cond-enser
GT361AC 208- 230/ 60/1 Air Cooled Full Cube 216 (98) 7.95 (631) 1 270 (122.47) 5.96 (473) 22 (1.84) n/a 12 15
GT361AHK Half Cube 255 (116) 7.31 (581) 1 332 (150.59) 5.12 (406) 23.6 (1.97) n/a 12 15
GGT361LC Liquid
Cooled
Full Cube 262 (119) 5.56 (441) 2 309 (140.16) 4.56 (362) 22.2 (1.85) 165.3 (13.79) 11.1 15
GT361LHK Half Cube 316 (143) 5.18 (411) 2 373 (169.19) 4.25 (337) 22.9 (1.91) 180.7 (15.08) 11.1 15
GT364AC 208-230 /60/1 Air Cooled Full Cube 215 (97) 7.57 (601) 2 269 (122.01) 5.68 (450) 22.1 (1.8) n/a 6.5 15
GT364AHK Half Cube 255 (116) 6.91 (548) 2 332 (150.59) 4.84 (384) 23.6 (1.97) n/a 6.5 15
GT364LC Liquid
Cooled
Full Cube 255 (115) 5.76 (457) 1 301 (136.53) 4.72 (374) 22 (1.8) 163.4 (13.63) 6 15
GT364LHK Half Cube 303 (137) 5.34 (424) 2 358 (162.38) 4.38 (347) 23.2 (1.94) 188.5 (15.73) 6 15

Note 1: 90/70 ratings based on 90°F (32.2°C) ambient and 70°F (21.1°C) water Standard Rating temperature operation. 70/50 estimated ratings based on 70°F (21.1°C) ambient and 50°F (10°C) water Standard Rating temperature operation.
Note 2: Minimum circuit Amps does not supersede the minimum circuit rating required by any code regulation for the branch circuit supplying the ice maker.

Energy-performance data are derived from testing in accordance with AHRI 810 and CAN/CSA C742 Standards for Performance Rating of Automatic Commercial
Ice Makers and verified by Intertek/ETL.

All models are certified in compliance with ANSI/UL 563 and CAN/CSA C22.2 No. 120 Standards for Safety by Intertek/ETL.


Please observe minimum circuit ampacity and maximum fuse size listed above. Fuse or HACR-type circuit breaker branch circuit protection within the range of minimum ampacity and maximum fuse size shall be provided or warranty may be voided. We reserve the right to make product improvements at any time. Specifications and design are subject to change without notice.

Dimensions/Weight

Condenser Dimensions - inches (cm)
Ship Weight
# (kg)
W D H
Air Cooled 30.1 (76.5) 25.7 (65.3) 16.9 (42.9) 180 (82)
Liquid Cooled 30.1 (76.5) 25.7 (65.3) 16.9 (42.9) 174 (79)
Commercial Ice machine GT 360 Dimensions
Commercial Ice Machine - GT-360