Commercial Ice Machines - GT360
Ice Machine
![]() |
| Commercial Ice Machine - GT360 - shown with B400 Bin |
![]() |
| KOLD-DRAFT Commercial Ice Machines produce full and half ice cubes, come with a 3-year warranty, and meet new energy standards! |
The Impact
Even if you don't need a ton of ice, you can still make a large impact with your customers. The KOLD-DRAFT GT360 Impact Series produces up to 321 lbs. of KOLD-DRAFT’s exclusive "square cube," known for its perfect shape, purity, hardness, and slower melt rate. That means it not only looks better, but also lasts longer in storage bins, cocktail sinks, drinks, salad bars, bags, and coolers. And KOLD-DRAFT equipment offers some of the best recovery rates in the industry. You get more ice, more often.
KOLD-DRAFT commercial ice machines feature a unique "upside-down" horizontal evaporator and water plate assembly. As water is sprayed upward into the evaporator cells, the pure water freezes first while particulates and air are forced out and dumped at the end of each cycle. This leaves only perfect crystal-clear cubes, nearly as pure as distilled water.
The GT360 Series' rugged unibody construction and time-proven design ensure reliable operation, greater water efficiency, and maximum ice-making capacity. Plus, they are energy efficient, using environmentally friendly R-404A refrigerant. To facilitate maintenance, the GT360 is serviceable from the front and is armed with our 3-year "bumper-to-bumper" warranty on all parts and labor.
General Specifications for GT360 Series
| Plumbing: | 3/8" FPT potable water inlet. 1" FPT bin drain. 3/4" I.D. flex tubing cuber drain. 3/8" FPT condenser (liquid-cooled) inlet. 1/2" FPT condenser (liquid-cooled) outlet. |
| Exterior Finish: | 300 Series stainless steel. |
| Refrigeration System: | Thermostatic expansion valve-controlled R-404A-HFC. |
| Clearance Requirements: | Allow 4" left side, 4" right side and back, and 1" top for ventilation and utility connections. |
| Condenser Heat Rejection: | BTUH/kW/Ton 4,700/1.38/0.39 avg. 5,850/1.71/0.49 peak |
Recommended Operating Requirements:
| Min. | Max. | |
| Room Air Temp. | 45ºF (7ºC) | 110ºF (43ºC) |
| Water Temperatures | 45ºF (7ºC) | 90ºF (32ºC) |
| Voltage 208-230 | 198V | 253V |
| Voltage 115 | 104V | 126V |
| Potable Water Pressure | 20 PSIG (137 kPa) | 100 PSIG (689 kPa) |
| Liquid-Cooled Condenser Pressure |
20 PSIG (137 kPa) | 100 PSIG (689 kPa) |
GT360 Series Daily Capacities: Lbs. of ice per 24 hours per unit
| Model Number |
Description | Capacity and Energy Input Ratings1 | Water Use1 gal/100# (l/kg) | Min. Circuit Amp2 | Max. Fuse Amps |
|||||||
| Volt/ Hz/Ph |
Cond-enser | Cube Size |
90/70 Ambient/ Water |
kWh/ 100# (kJ/kg) |
Tier | 70/50 Ambient/ Water |
kWh/ 100# (kJ/kg) |
Pot-able | Cond-enser | |||
| GT361AC | 208- 230/ 60/1 | Air Cooled | Full Cube | 216 (98) | 7.95 (631) | 1 | 270 (122.47) | 5.96 (473) | 22 (1.84) | n/a | 12 | 15 |
| GT361AHK | Half Cube | 255 (116) | 7.31 (581) | 1 | 332 (150.59) | 5.12 (406) | 23.6 (1.97) | n/a | 12 | 15 | ||
| GGT361LC | Liquid Cooled |
Full Cube | 262 (119) | 5.56 (441) | 2 | 309 (140.16) | 4.56 (362) | 22.2 (1.85) | 165.3 (13.79) | 11.1 | 15 | |
| GT361LHK | Half Cube | 316 (143) | 5.18 (411) | 2 | 373 (169.19) | 4.25 (337) | 22.9 (1.91) | 180.7 (15.08) | 11.1 | 15 | ||
| GT364AC | 208-230 /60/1 | Air Cooled | Full Cube | 215 (97) | 7.57 (601) | 2 | 269 (122.01) | 5.68 (450) | 22.1 (1.8) | n/a | 6.5 | 15 |
| GT364AHK | Half Cube | 255 (116) | 6.91 (548) | 2 | 332 (150.59) | 4.84 (384) | 23.6 (1.97) | n/a | 6.5 | 15 | ||
| GT364LC | Liquid Cooled |
Full Cube | 255 (115) | 5.76 (457) | 1 | 301 (136.53) | 4.72 (374) | 22 (1.8) | 163.4 (13.63) | 6 | 15 | |
| GT364LHK | Half Cube | 303 (137) | 5.34 (424) | 2 | 358 (162.38) | 4.38 (347) | 23.2 (1.94) | 188.5 (15.73) | 6 | 15 | ||
Note 1: 90/70 ratings based on 90°F (32.2°C) ambient and 70°F (21.1°C) water Standard Rating temperature operation. 70/50 estimated ratings based on 70°F (21.1°C) ambient and 50°F (10°C) water Standard Rating temperature operation. Energy-performance data are derived from testing in accordance with AHRI 810 and CAN/CSA C742 Standards for Performance Rating of Automatic Commercial All models are certified in compliance with ANSI/UL 563 and CAN/CSA C22.2 No. 120 Standards for Safety by Intertek/ETL. |
||||||||||||
Please observe minimum circuit ampacity and maximum fuse size listed above. Fuse or HACR-type circuit breaker branch circuit protection within the range of minimum ampacity and maximum fuse size shall be provided or warranty may be voided. We reserve the right to make product improvements at any time. Specifications and design are subject to change without notice.
Dimensions/Weight
| Condenser | Dimensions - inches (cm) |
Ship Weight # (kg) |
||
| W | D | H | ||
| Air Cooled | 30.1 (76.5) | 25.7 (65.3) | 16.9 (42.9) | 180 (82) |
| Liquid Cooled | 30.1 (76.5) | 25.7 (65.3) | 16.9 (42.9) | 174 (79) |
![]() |
| Commercial Ice Machine - GT-360 |
ALL KOLD-DRAFT Commercial Ice Machines meet the California Energy Standards - read about the California Commercial Ice Machines Test - ( PDF - Test Laboratory Information For Commercial Refrigerators, Commercial Refrigerator-Freezers And Commercial Freezers)