Commercial Ice Machines

Commercial Ice Machines - GT560

Ice Machine GT560

Commercial Ice Machine T-270
Commercial Ice Machine - GT560 Series Shown with B400 Bin
KOLD-DRAFT Commercial Ice machines T270 Features
KOLD-DRAFT Commercial Ice Machines produce full and half ice cubes, come with a 3-year warranty, and meet new energy standards!

The Workhorse

What you would expect from a Classic: high quality, lasting value, and better ice.
The KOLD-DRAFT GT560 Classic Series produces up to 520 lbs. of KOLD-DRAFT - exclusive "square cube" known for its perfect shape, purity, hardness, and slower melt rate. That means it not only looks better, but also lasts longer in storage bins, cocktail sinks, drinks, salad bars, bags, and coolers. And KOLD-DRAFT equipment offers some of the best recovery rates in the industry. You get more ice, more often.

KOLD-DRAFT commercial ice machinesfeature a unique "upside-down" horizontal evaporator and water plate assembly. As water is sprayed upward into the evaporator cells, the pure water freezes first while particulates and air are forced out and dumped at the end of each cycle. This leaves only perfect crystal-clear cubes, nearly as pure as distilled water.

The GT560 Series’ rugged unibody construction and time-proven design ensure reliable operation, greater water efficiency, and maximum ice-making capacity. Plus, they are energy efficient, using environmentally friendly R-404A refrigerant. To facilitate maintenance, the GT560 is serviceable from the front and is armed with our 3-year "bumper-to-bumper" warranty on all parts and labor.

 

 

 

 

 

 

 

 

 

General Specifications for GT560 Series

Plumbing: 3/8" FPT potable water inlet.
1" FPT bin drain.
3/4" I.D. flex tubing cuber drain.
3/8" FPT condenser (liquid-cooled) inlet.
1/2" FPT condenser (liquid-cooled) outlet.
Exterior Finish: 300 Series stainless steel.
Refrigeration System: Thermostatic expansion valve-controlled R-404A-HFC.
Clearance Requirements: Allow 4" left side, 4" right side and back, and 1" top for ventilation and utility connections.
Condenser Heat Rejection: BTUH/kW/Ton
6,500/1.91/0.54 avg.
8,750/2.6/0.729 peak

 

Recommended Operating Requirements:

  Min. Max.
Room Air Temp. 45ºF (7ºC) 110ºF (43ºC)
Water Temperatures 45ºF (7ºC) 90ºF (32ºC)
Voltage 208-230 198V 253V
Voltage 115 104V 126V
Potable Water Pressure 20 PSIG (137 kPa) 100 PSIG (689 kPa)
Liquid-Cooled Condenser
Pressure
20 PSIG (137 kPa) 100 PSIG (689 kPa)

 

Commercial Ice Machine - GT560 Series Daily Capacities: Lbs. of ice per 24 hours per unit

Model
Number
Description Capacity and Energy Input Ratings1 Water Use1 gal/100# (l/kg) Min. Circuit Amp Max.
Fuse Amps
Volt/
Hz/Ph
Condenser Cube
Size
90/70
Ambient/ Water
kWh/ 100#
(kJ/kg)
Tier 70/50
Ambient/ Water
kWh/ 100#
(kJ/kg)
Potable Cond-enser
GT561AC 115/6 0/1 Air Cooled Full Cube 369 (167.22) 6.63 (526) 1 458 (207.74) 5.04 (400) 16.6 (1.39) n/a 18.6 30
GT561AHK Half Cube 453 (205.44) 6.19 (491) 1 575 (260.81) 4.52 (358) 20.4 (1.7) n/a 18.6 30
GT561LC Liquid
Cooled
Full Cube 447 (202.56) 5.15 (408) 1 510 (231.33) 4.43 (351) 13.2 (1.1) 137.4 (11.47) 17.7 30
GT561LHK Half Cube 500 (226.89) 4.85 (384) 1 580 (263.08) 4.07 (323) 17.1 (1.43) 175.9 (14.68) 17.7 30
GT564AC 208-230/ 60/1 Air Cooled Full Cube 380 (172.19) 6.88 (545) 1 471 (213.64) 5.23 (415) 16.7 (1.39) n/a 9.5 15
GT564AHK Half Cube 433 (196.49) 5.99 (475) 1 550 (249.47) 4.37 (346) 18.4 (1.54) n/a 9.5 15
GT564LC Liquid
Cooled
Full Cube 429 (194.43) 5.14 (407) 1 489 (221.80) 4.42 (350) 16.9 (1.41) 175.6 (14.65) 9.1 15
GT564LHK Half Cube 494 (224.26) 4.73 (375) 1 573 (259.90) 3.97 (315) 15.9 (1.33) 144.2 (12.03) 9.1 15

Note 1: 90/70 ratings based on 90°F (32.2°C) ambient and 70°F (21.1°C) water Standard Rating temperature operation. 70/50 estimated ratings based on 70°F (21.1°C) ambient and 50°F (10°C) water Standard Rating temperature operation.
Note 2: Minimum circuit Amps does not supersede the minimum circuit rating required by any code regulation for the branch circuit supplying the ice maker.

Energy-performance data are derived from testing in accordance with AHRI 810 and CAN/CSA C742 Standards for Performance Rating of Automatic Commercial
Ice Makers and verified by Intertek/ETL.

All models are certified in compliance with ANSI/UL 563 and CAN/CSA C22.2 No. 120 Standards for Safety by Intertek/ETL.


Please observe minimum circuit ampacity and maximum fuse size listed above. Fuse or HACR-type circuit breaker branch circuit protection within the range of minimum ampacity and maximum fuse size shall be provided or warranty may be voided. We reserve the right to make product improvements at any time. Specifications and design are subject to change without notice.


Commercial Ice Machines Dimensions/Weight

Condenser Dimensions - inches (cm)
Ship Weight
# (kg)
W D H
Air Cooled 30.1 (76.5) 25.7 (65.3) 30.7 (78) 228 (103)
Liquid Cooled 30.1 (76.5) 25.7 (65.3) 30.7 (78) 218 (99)
Commercial Ice machine GT 560 Dimensions
Commercial Ice Machine - GT-560

 

 

ALL KOLD-DRAFT Commercial Ice Machines meet the California Energy Standards - read about the California Commercial Ice Machines Test - ( PDF - Test Laboratory Information For Commercial Refrigerators, Commercial Refrigerator-Freezers And Commercial Freezers)

 

 

© 2010 KOLD-DRAFT, All Rights Reserved US Made High Quality US-Made Commercial Ice Machines