Commercial Ice Machine GB450 | B310

ICE CUBER

Ice Machine GB450 | B310
Ice Machine - GB450 Series Ice Cuber
on a B310 Bin
Ice machine GB450 | B310 Dimensions
Ice Machine - Stores 310 lbs. of ice,
based on 35 lbs./cu.ft. at 90% of bin volume.

Up To 460 lb. Daily Capacity

SIMPLICITY BY DESIGN

The KOLD-DRAFT 450 Series Classic Ice Cuber produces up to 460 lbs. of ice per day. It is engineered with rugged unibody construction and its time-proven design ensures reliable operation, greater water efficiency and maximum ice-making capacity. Serviceability is from the front and the use of environmentally-friendly R-404A refrigerant gives greater efficiency.

The KOLD-DRAFT B310 bin holds 310 lbs. of ice. The B310 has a stainless steel interior liner and stainless steel exterior front, sides and back. It is insulated with 2” of expanded foam insulation and comes with sliding clear acrylic doors for easy ice access and visibility.

THE HIGHEST QUALITY ICE

Ice that’s free from impurities. Ice that’s uniformly shaped ensuring maximum displacement and ease of handling.
Ice that sparkles, melts slowly and looks like ice should look. Three sizes of KOLD-DRAFT cubes to choose from that meet your exact needs. Full cubes, half cubes and cubelets – the highest quality ice.

STACKABILITY

GB Series Classic Ice Cubers are stackable with each other and can be stacked on existing KOLD-DRAFT GB Series Classic and Electronic Cubers. This unique “Add-A-Unit” feature will give you unsurpassed flexibility in ice-making capacity. So as your business grows, so can your ice capacity without using valuable floor space.

KOLD-DRAFT’s Commercial Ice Machine Warranty

KOLD-DRAFT’s warranty provides five years parts and labor on the entire machine and five years on the compressor and evaporator parts. More on the KOLD-DRAFT ice machine warranty.

 

General Specifications for GB450 Commercial Ice Machine Series:

PLUMBING: 1/4” FPT potable water inlet.
Condenser water supply inlet: 3/8” FPT
1” FPT bin drain.
Condenser drain: 1/2” FpT
3/4” I.D. flex tubing cuber drain.

EXTERIOR FINISH:
Type 300 Series stainless steel.

REFRIGERATION SYSTEM:
3/4 Hp Compressor. Thermostatic expansion-valve controlled. R-404A HFC.

CLEARANCE REQUIREMENTS:
Allow 4” left side, 8” right side and 6” back and top for ventilation and utility connections.

ICE MACHINE RECOMMENDED OPERATING REQUIREMENTS:

  Min. Max.
Air Temperatures 45º 90ºF
Water Temperatures 45º 90ºF
Water Pressures 20-100 pSIG
Voltage 104-126V/198-253V


GB450 Series Daily Capacities: Lbs. of ice per 24 hours per unit

GB451W/GB454W Water-cooled GB451A/GB454A air-cooled
Incoming
Water Temp., ºF
A mbient Temp., ºF Incoming Water Temp., ºF Ambient Temp., ºF
70º 90º 70º 90º
50º 460lbs. | 209kg 50ºF (10ºC) 460lbs. | 209kg
70º 443lbs. | 201kg 70ºF (21ºC) 393lbs. | 178kg
The above capacities are based on (HK) Half Cube and can be increased or reduced between 5-15% depending on cube size or by adjusting the cuber to produce concave cubes.

KOLD-DRAFT ice machines are designed for indoor use and for operation within the above listed limits. Any deviation may eliminate coverage of factory warranties. Failures caused by operation on voltages other than indicated on model nameplates are not considered defects.

 

GB450 | B310 - ICE MACHINE - ICE CUBER

MODEL ICE
PRODUCTION
PER 24
HOURS 1
ELECTRICAL SUPPLY
CHARACTERISTICS,
V-HZ-PH
NUMBER
OF WIRES PLUS
GROUND
MINIMUM
CIRCUIT
AMPACITY 2
MAXIMUM
FUSE
SIZE, A
CONDENS- ER
UNIT TYPE
SHIPPING
WEIGHTS
GB451A* 460 115-60-1 2 19.9 30 air- cooled 197lbs. | 89kg
GB451W* 460 115-60-1 2 16.4 25 water-cooled 195lbs. | 88kg
GB454A* 460 208/230-60-1 2 11.9 20 air- cooled 197lbs. | 89kg
GB454W* 460 208/230-60-1 2 11.3 15 water-cooled 195lbs. | 88kg
GB457A* 460 220-50-1 2 - - air- cooled 197lbs. | 89kg
GB457W* 460 220-50-1 2 - - liquid-cooled 195lbs. | 88kg
*KOLD-DRAFT ICE: To specify described cube size place “K” cubelet, “HK” half-cube, or “C” full cube in place of *asterisk in model numbers.

1 Production capacity at 50°F water and 70°F air.
2 Use this value to determine minimum wire size per National Electric Code Requirements.

Please observe minimum circuit ampacity and maximum fuse size listed above. Fuse or HACR-type circuit breaker branch circuit protection within the range of minimum ampacity and maximum fuse size shall be provided or warranty may be voided. We reserve the right to make product improvements at any time. Specifications and design are subject to change without notice.

 

GB450 | B310 ICE MACHINE SCHEMATIC

Ice Machine GB450 | B310 Schematic

Click to view enlarged GB450 | B550 Ice Machine Schematic

 

View GB450 | B310 Ice Commercial Machine Specs (PDF)

 

More About Our Commercial Ice Machines and Commercial Ice Makers

 

 

© 2010 KOLD-DRAFT, All Rights Reserved US Made High Quality US-Made Commercial Ice Machines