Ice Machine GT350 | B400
ICE CUBER
![]() |
| Ice Machine - GT350 Series Ice Cuber on a B400 Bin |
![]() |
| Ice Machine - GT351W on a B400 Bin. Stores 400 lbs. of ice, based on 35 lbs./cu.ft. at 90% of bin volume. |
Up To 321 lb. DaIly Capacity
SIMPLICITY BY DESIGN
The KOLD-DRAFT 350 Series Classic Ice Cuber produces up
to 321 lbs. of ice per day. It is engineered with rugged
unibody construction and its time-proven design ensures >
reliable operation, greater water efficiency and maximum
ice-making capacity. Serviceability is from the front and the
use of environmentally-friendly R-404a refrigerant gives
greater efficiency.
The KOLD-DRAFT B400 Bin holds 400 lbs. of ice. The B400
has a stainless steel interior liner and stainless steel exterior
front, sides and back. It is insulated with 2” of expanded
foam insulation and comes with an insulated stainless steel
lift up door that will withstand years of hard use.
THE HIGHEST QUALITY ICE
Ice that’s free from impurities. Ice that’s uniformly shaped ensuring maximum displacement and ease of handling. Ice that sparkles, melts slowly and looks like ice should look. Three sizes of KOLD-DRAFT cubes to choose from that meet your exact needs. Full cubes, half cubes and cubelets – the highest quality ice.
A LOT OF ICE IN A LITTLE SPACE
The KOLD-DRAFT GT Series Slimline Cuber is only 28 3/8” wide and is engineered and built to fit in small areas and produce up to 321 lbs. of ice per day. GT Series Slimline bins are available with storage capacities of 230 or 400 lbs.
KOLD-DRAFT’s Ice Machine Warranty
KOLD-DRAFT’s warranty provides five years parts and labor on the entire machine and five years on the compressor and evaporator parts. More on the KOLD-DRAFT ice machine warranty.
General Specifications for GT350 Ice Machine Series:
PLUMBING: 1/4” FPT potable water inlet.
Condenser water supply inlet: 3/8” FPT
3/4” FPT bin drain.
Condenser drain: 1/2” FPT
3/4” I.D. flex tubing cuber drain.
EXTERIOR FINISH:
Type 300 Series stainless steel.
REFRIGERATION SYSTEM:
5100 bTU Compressor. Thermostatic expansion-valve controlled. R-404A.
CLEARANCE REQUIREMENTS:
Allow 6” minimum clearance at back, top and sides for ventilation and utility connections.
RECOMMENDED OPERATING REQUIREMENTS:
| Min. | Max. | |
| Air Temperatures | 45º | 90ºF |
| Water Temperatures | 45º | 90ºF |
| Water Pressures | 20-100 PSIG | |
| Voltage | 104-126V/198-253V | |
GT550 Series Daily Capacities: Lbs. of ice per 24 hours per unit
| GT551W Water-Cooled | GT551A Air-Cooled | ||||
| Incoming Water Temp., ºF |
A mbient Temp., ºF | Incoming Water Temp., ºF | Ambient Temp., ºF | ||
| 70º | 90º | 70º | 90º | ||
| 50º | 321lbs. | 145kg | – | 50º | 314lbs. | 143kg | – |
| 70º | – | 299lbs. | 136kg | 70º | – | 247lbs. | 112kg |
| The above capacities are based on (HK) Half Cube and can be increased or reduced between 5-15% depending on cube size or by adjusting the cuber to produce concave cubes. KOLD-DRAFT ice machines are designed for indoor use and for operation within the above listed limits. any deviation may eliminate coverage of factory warranties. Failures caused by operation on voltages other than indicated on model nameplates are not considered defects. |
|||||
GT350 | B400 - ICE MACHINE - ICE CUBER
| MODEL | ICE PRODUCTION PER 24 HOURS 2 |
ELECTRICAL SUPPLY CHARACTERISTICS, V-HZ-PH |
NUMBER OF WIRES PLUS GROUND |
MINIMUM CIRCUIT AMPACITY 3 |
MAXIMUM FUSE MODEL SIZE, A |
CONDENS- ER UNIT TYPE |
SHIPPING WEIGHTS |
| GT351A* | 314 | 115-60-1 | 2 | 15.6 | 25 | air- cooled | 164lbs. | 74kg |
| GT351W* | 321 | 115-60-1 | 2 | 14.4 | 20 | water-cooled | 159lbs. | 72kg |
| GT354A* | 314 | 208/230-60-1 | 2 | 9.3 | 15 | air- cooled | 164lbs. | 74kg |
| GT354W* | 321 | 208/230-60-1 | 2 | 8.6 | 15 | water-cooled | 159lbs. | 72kg |
| GT357A* | 314 | 220-50-1 | 2 | - | - | air- cooled | 164lbs. | 74kg |
| GT357W* | 321 | 220-50-1 | 2 | - | - | water-cooled | 159lbs. | 72kg |
| *KOLD-DRAFT ICE: To specify described cube size place “K” cubelet, “HK” half-cube, or “C” full cube in place of *asterisk in model numbers. 1 Production capacity at 50ºF water and 70°F air. 2 Use this value to determine minimum wire size per National Electric Code Requirements. Please observe minimum circuit ampacity and maximum fuse size listed above. Fuse or HACR-type circuit breaker branch circuit protection within the range of minimum ampacity and maximum fuse size shall be provided or warranty may be voided. We reserve the right to make product improvements at any time. Specifications and design are subject to change without notice. |
|||||||
GT350 | B400ICE MACHINE SCHEMATIC
![]() |
View GT350 | B400 Ice Machine Specs (PDF)
More About Our Commercial Ice Machines and Commercial Ice Makers
- See why KOLD-DRAFT ice machines make the "Best Ice in the World"
- Read more about KOLD-DRAFT's Ice Machine Warranty, Five Years on Parts and Labor
- Check out our "Green" Ice - ALL KOLD-DRAFT Commercial Ice Machines are Energy Efficient!
- Learn how KOLD-DRAFT Ice Machines Turned Ice-Making Upside Down!
- Not sure how much ice you need? Check out our Ice Machine Usage Guide
- See our full line of commercial ice machines
- Read more on our commercial ice makers for all markets
- Please contact us with any questions regarding commercial ice machines for your market